| Product Name: | Three Phase Electronic KWh Meter | Installation: | Panel Installation |
|---|---|---|---|
| Rated Current: | AC 1A/ 5A | Display: | Digital LCD Display |
| Power Supply: | AC 85~265V; DC24V | ||
| Highlight: | Data Storage Energy Meter,Acrel AMC96L-E4 Energy Meter,Intelligent Electricity Collection Energy Meter |
||
Product Description
AMC96L-E4 series intelligent electricity collection and monitoring device
AMC96L-E4 series integrates the measurement of power parameters, power monitoring and assessment management, and is very suitable for real-time power monitoring systems. It can directly replace conventional power transmitters and measuring instruments. As an intelligent and digital front-end acquisition component, the instrument has been widely used in various control systems, SCADA systems and energy management systems.
Funtions
![]()
Dimensions
![]()
Front Panel
![]()
Parameters
| Technical parameters | Value | |||
| Input | Connection | Single phase-2-wire, 3-phase-3-wire, 3-phase-4-wire; | ||
| Frequency | 45-65Hz | |||
| Voltage |
Rating: Single-phase: AC 100V, 400V Three-phase: AC 3×57.7V/100V(100V), 3×220V/380V(400V), 3×380V/660V(660V)(96 size only); |
|||
| Overload:1.2 fold rating (continuous): 2 fold rating for 1 second; | ||||
| Power consumption:< 0.5VA; | ||||
| Current | Rating: AC 1A, 5A | |||
| Overload:1.2 fold rating(continuous);10 fold rating for 1 second; | ||||
| Power consumption:< 0.5VA; | ||||
| Output | Electric energy | Output mode:open-collector photo-coupler pulse; | ||
| Pulse constant: 10000imp/kWh(settable), see wiring diagram for details; | ||||
| Communication |
RS485port, Modbus -RTU protocol, DLT645 protocol(versions 07 and 97); Baud rate 1200 ~ 38400; |
|||
| Function | Switching input | Dry contact input, built-in power supply; if the model is KA, it is AC 220V active; | ||
| Switching output | Output mode: Relay normally open contact output; | |||
| Contact capacity: AC 250V/3A, DC 30V/3A; | ||||
| Analog output | 4 - 20mA | |||
| Accuracy class | Frequency: 0.05Hz; Current, Voltage: 0.2 class; Reactive power: 1.0 class; Reactive Electric energy: 1.0 class; Active power: 0.5 class; Active electric energy: 0.5 class; 2° - 31° Harmonic measurement: ±1%; | |||
| Power supply |
AC/DC 85-265V or DC24V(±20%) or DC48V(±20%); Power consumption≤10VA; |
|||
| Security | Power frequency withstand voltage |
Between Power supply//Switching Output// Current Input//Voltage Input and Transmitting// Communication //Pulse Output//Switching input AC 2 kV 1min; Between Power supply, Switching output, Current Input, Voltage Input AC 2 kV 1min; Between Transmitting, Communication, Pulse Output, Switching input AC 1kV 1 min; |
||
| Insulation resistance | Input, Output end to machine enclosure >100MΩ; | |||
| Environment | Temperature | Work: -25°C~+65°C; Storage: -40°C ~+80°C; | ||
| Humidity | ≤93%RH Non-condensing; | |||
| Altitude | ≤2500m | |||