● THD with 63rd Harmonics
● K-Factor and Crest Factor
● Unbalance & Phase Angles
● Demands and Multi-Tariff energy
● Max/Min Log with Timestamp
Contact Person : Dina Huang
Phone Number : 18761502682
WhatsApp : +8618761502682
Detail Information |
|||
Display Type: | Analog And Digital | Phase: | Three Phase |
---|---|---|---|
Measuring Energy Range: | AC/DC 85V~265V Or AC/DC 115~415V | Accuracy Class: | 0.5s |
Output Voltage: | AC/DC 85V~265V Or AC/DC 115~415V | Operating Temperature: | -20-65℃ |
Dimensions: | 96*96*65mm | Display: | LCD Display |
Communication: | RS485 Port MODBUS-RTU Protocol | Certificate: | CE ISO9001 |
Installation: | Panel Mounted | Frequency: | Range:45-65Hz |
Consumption: | ≤15VA | Function: | Multi Rate (time-of -use) Energy Measurement |
Auxiliary Power Supply: | AC/DC 85V~265V Or AC/DC 115~415V | Accuracy: | Voltage,current And Power:class 0.5s |
Relay: | 3A/AC250V, 3A/DC30V | Selling Units: | Single Item |
Single Package Size : | 9.6X9.6X9.2 Cm | Single Gross Weight: | 0.800 Kg |
Package Type: | It Is Packed In A Crash Bag And Then Put Into A Cardboard Box. | ||
Highlight: | 50Hz Programmable Power Meter,65mm Programmable Power Meter,96mm Multifunction Power Meter |
Product Description
Connection
|
|
3 phase 3 wire,3 phase 4 wire
|
|
Frequency
|
|
50Hz
|
|
Input voltage
|
Rated current
|
AC 100V,110V,400V,690V
|
|
|
Overload
|
1.2 times rated value(continuous);2 times rated value(1 second)
|
|
|
Consumption
|
<0.5VA
|
|
Input current
|
Rated current
|
AC 1A,5A
|
|
|
Overload
|
1.2 times rated value(continuous);10times rated value(1 second)
|
|
|
Consumption
|
<0.5VA
|
|
Accuracy
|
voltage,current and power
|
Class 0.5S(APM800,APM801)
Class 0.2S(APM801,APM830)
|
|
|
Active power
|
|
|
|
Reactive power
|
Class 2
|
|
|
harmonic
|
1%(2-42nd),2%(43-63rd)
|
|
Switch inputs
|
|
Passive contact inputs,built-in power supply
|
|
Relay outputs
|
|
Contact type:open contact in main part,changeover contact in module
Pulse capacity;3A/AC250V 3A/DC30V
|
|
Pulse output of energy
|
|
Output mode:Optocoupler pulse with open collector
Pulse constant:4000(5A),8000(1A)imp/kWh
|
|
Analog outputs
|
|
DC0-20mA,4-20mA,0-5V,1-5V output,accuracy class 0.5%,
Load resistance≤500Ω
|
|
Analog inputs
|
|
DC0-20mA,4-20mA,0-5V,1-5V output,accuracy class 0.5%
|
|
Storage card
|
|
Standard capacity:4G,TF card up to 32G capacity
|
|
Communication
|
|
RS485(Modbus-RTU)
|
|
Auxiliary power supply
|
|
AC/DC 85-265V or AC/DC 115-415V
|
|
Environment
|
Operating temperature
|
-20~65℃
|
|
|
Storing temperature
|
-20~70℃
|
|
|
Humidity
|
≤95%
|
|
|
Altitude
|
≤2500m
|
Enter Your Message