Acrel Class 0.5S Data Center Power Meter Monitor Device AMC16MA
Contact Person : Dina Huang
Phone Number : 18761502682
WhatsApp : +8618761502682
Minimum Order Quantity : | 1pc | Packaging Details : | carton |
---|---|---|---|
Delivery Time : | 5-8 work days | Payment Terms : | T/T |
Supply Ability : | 5000pc/day |
Place of Origin: | China | Brand Name: | Acrel |
---|---|---|---|
Certification: | CE | Model Number: | AMC16Z-FAK48 |
Detail Information |
|||
Rated Voltage: | 220V AC | Product Name: | Multi Channel Din Rail Ac Power Meter |
---|---|---|---|
Measurement Range: | ±20% | IP Grade: | IP20 |
Altitude: | ≤2500m | ||
Highlight: | IDC branch circuit monitoring module,Data Center branch circuit monitoring module,3 phase branch circuit monitoring module |
Product Description
AMC16-FAK48 Three Phase Branch Circuit Monitoring Module for IDC Data Center
Main features:
Standard and certificate: CE; IEC;
Parameters:
Instrument model | AMC16Z-FAK48 | ||
Measurement parameters | Voltage, current, frequency, active power, reactive power, power factor, active power, reactive power, switching state; | ||
2nd-31st times harmonics | |||
Bus Voltage | Rated | 220VAC | |
Measurement | ±20% | ||
Overload | Instantaneous voltage 2 times/second | ||
Outgoing line current | Rated | 50mA | |
Range | 0.125~60mA | ||
Overload | Duration 1.2 times, instantaneous 10 times/second | ||
Input frequency | 45~60Hz | ||
Measurement accuracy | Outgoing line | Voltage/current/active power/active energy level 0.5, reactive power/reactive energy level 1; | |
Auxiliary power supply | Power supply by AMC16Z-ZA; DC 12-24V when used alone; | ||
Environment | Temperature | Working: -15℃~55℃; Storage: -25℃~70℃; | |
Humidity | Relative humidity | ||
Altitude | ≤2500m | ||
Communication | RS485/Modbus-RTU | ||
Installation method | DIN35mm Guide rail or bottom plate mounting; | ||
IP grade | IP20 | ||
Class of pollution | 2 | ||
Safety | Insulation | All terminals and the insulation resistance between the conductive pieces not below 100 mΩ; | |
Withstand voltage | A-channel voltage and current signal // B-channel voltage and current signal // other ports meet AC2kV 1min between pairs, leakage current should be less than 2mA, no breakdown or flash over phenomenon; | ||
Electromagnetic compatibility | Anti static interference | Level 4 | |
Resistance to radiation of radio frequency electromagnetic | Level 3 |
Details:
1. General:
AMC16Z series AC precision power distribution monitoring device is specially designed for data center server power management. The device has exquisite design and can provide A+B 2 incoming and 96 outgoing electrical parameters, the input and output switch and the status of lightning protection device with real data. -Time tracking. All alarm thresholds of measurement channels can be configured separately. Excess output immediately activates the system's acoustic warning. A highly integrated monitoring circuit is realized in the volume of traditional instruments.
2. Functions:
3. Dimensions:
4. Terminals:
5. Wiring:
6. Network: