Acrel Class 0.5S Data Center Power Meter Monitor Device AMC16MA
Contact Person : Dina Huang
Phone Number : 18761502682
WhatsApp : +8618761502682
Detail Information |
|||
Active Power: | Class 0.5S | Reactive Power: | Class 2 |
---|---|---|---|
Range: | 45-65Hz | Auxiliary Power Supply: | AC/DC 85V~265V Or AC/DC 115~415V |
Output Mode: | Optocoupler Pulse With Open Collector | Dimension(L*W*H): | 180*94.3*75mm |
Installation: | DIN Rail 35mm | ||
Highlight: | class 2 Multi Circuit Energy Meter,65Hz Multi Circuit Energy Meter,65Hz multi circuit power meter |
Product Description
AMC16Z-FDK48 monitor the full power parameters and switch state of 48 branches of double-channel DC outlet, 1-channel RS485 communication and phase adjustment.
Product Selection
Name | Pic | Model | Main Function |
HMI
|
ATP007kt ATP010kt |
1.7 or 10 inch touch screen 2.Real-time monitoring and display voltage,current,power,energy,power quality,switch status,waveform curve and so on. 3.monitoring device alarm,communication and other parameters can be configured on the screen. 4. 2 RS485 and 1 Ethernet interface,and data can be uploaded by RS485 or RJ45. |
|
AC incoming line monitoring module | AMC16Z-ZA |
1. Installation:DIN rail 35mm 2. Measurement:A+B independent 3 phase circuits, 6DI2DO,2 leakage current,1 temp. and humidity. 3. With DC 24V output power supply for outgoing line module and touch screen. 4. Communication:RS485 Modbus RTU |
|
AC outgoing line monitoring module |
AMC16Z-FAK24 AMC16Z-FAK48 |
1. Installation:DIN rail 35mm 2. Can measure up to 16 circuit 3 phase or 48 circuit single phase 3. DC24V power supply 4. Communication:RS485 modbus RTU
|
|
AC outgoing line current transformer | AKH-0.66W |
Current ratio:100A/50mA Common Specification: 100A/50mA |
|
DC incoming line monitoring module | AMC16Z-ZD |
1.Installation:DIN Rail 35mm 2.Measurement:A+B independent circuits,6DI2DO,1 temp. And humidity. 3.With DC 24V output power supply for outgoing line module and touch screen. 4.Communication:RS485 modbus RTU |
|
DC outgoing line monitoring module |
AMC16Z-FDK24 AMC16Z-FDK48 |
1. Installation:DIN Rail 35mm 2. Can measure up to 48 circuits DC outgoing line 3. DC24V power supply 4. Communication:RS485 modbus RTU
|
|
DC incoming line insulation monitoring module | AMC16Z-ZJY |
1. Installation:DIN Rail 35mm 2. Measure A+B independent DC circuit ground insulation resistance of main bus 3. DC24V power supply 4. Communication:RS485 modbus RTU |
|
DC outgoing line insulation monitoring module | AMC16Z-FJY |
1. Installation:DIN Rail 35mm 2. Measure 24 circuits ground insulation resistance of DC outgoing line |
|
DC outgoing line hall effect current sensor | AHKC-BS |
Current ratio:100A/5V Common Specification: 100A/5V |
Enter Your Message