Send Message
Contact Us

Contact Person : Dina Huang

Phone Number : 18761502682

WhatsApp : +8618761502682

Free call

Acrel AIM-M100 Medical Intelligent Insulation Detector Fault Location Device Din Rail Installation For Medical IT System

Minimum Order Quantity : 1pc Packaging Details : carton
Delivery Time : 2-3 work days Payment Terms : T/T
Supply Ability : 5000pc/day
Place of Origin: China Brand Name: Acrel
Certification: CE Model Number: AIM-M100

Detail Information

Product Name: Medical Intelligent Insulation Detector Power Supply: AC220V
Installation: Din Rail Application: Medical IT System
Communication: RS485 Modbus RTU
High Light:

din rail installation insulation detector

,

Medical intelligent insulation detector

,

IT system insulation detector

Product Description

AIM-M100 medical intelligent insulation monitor

 

Main functions:

  • Insulation testing
  • Transformer temperature monitoring
  • Overload monitoring
  • Wiring status monitoring
  • 2 relay outputs
  • 2-way RS485 communication
  • Dot matrix LCD display
  • 6-mode guide rail housing

 


Acrel AIM-M100 Medical Intelligent Insulation Detector Fault Location Device Din Rail Installation For Medical IT System 0Acrel AIM-M100 Medical Intelligent Insulation Detector Fault Location Device Din Rail Installation For Medical IT System 1

 

Technical parameters

 

Model AIM-M10 AIM-M100 AIM-M200
Power supply Voltage AC220V±10% AC220V±10% DC24V±25%
  Frequency 50/60Hz 50/60Hz -
  Max power consumption <5W <8W <3W
Insulation monitoring Insulation resistance measuring range 10-999kΩ
  Relative percentage accuracy 0—±10%
  Alarm value range 10—995kΩ 50—999kΩ 50—999kΩ
  Response time <2s
  Measuring voltage <12V
  Measuring current <42uA <50uA <50uA
Current monitoring Measuring range 2.1-50A
  Alamm value range 5-50A
  Measurement accuracy ≤±5%
Temperature monitoring Thermal resistor PT100
  Measuring range -50—+200℃
  Alarm value range 0—+200℃
Alarm output Output type 1 channel relay output 2 channels relay output(programmable) 2 channels relay output
  Contact rating

AC 250V/3A

DC 30V/3A

AC 250V/3A

DC 30V/3A

AC 250V/3A DC 30V/3A
Environment Working temperature -10—+55℃
  Storage temperature -20—+70℃
  Relative humidity 5%-95%,non-condensing
  Altitude ≤2500m
Communication RS485 interface,Modbus-RTU protocol RS485 interface,Modbus-RTU protocol

CAN interface, custom protocol,

RS485 interface, Modbus-RTU protoco

 

Certificate


Acrel AIM-M100 Medical Intelligent Insulation Detector Fault Location Device Din Rail Installation For Medical IT System 2

 

 

Company


Acrel AIM-M100 Medical Intelligent Insulation Detector Fault Location Device Din Rail Installation For Medical IT System 3

 

Contact us


Acrel AIM-M100 Medical Intelligent Insulation Detector Fault Location Device Din Rail Installation For Medical IT System 4

You Might Be Into These
Get in touch with us

Enter Your Message

Celia.Tsui@email.acrel.cn
+8618761502682
18761502682
18761502682
18761502682