Acrel Class 0.5S Data Center Power Meter Monitor Device AMC16MA
Contact Person : Dina Huang
Phone Number : 18761502682
WhatsApp : +8618761502682
Detail Information |
|||
Measurement: | A+B Independent 2 Channels Three-phase Inlet | Frequency: | 45~65Hz |
---|---|---|---|
Installation: | DIN 35 Mm | Communication: | RS485 Modus Rtu |
Harmonic: | 2nd-63rd | Rated U And I: | AC 220/380V |
Highlight: | Acrel Multi AC Monitor Energy Meter,35mm AC Multi Circuit Energy Meter,Three Phase DIN Rail Meter |
Product Description
With the rapid development of data center, the energy consumption problems about the data center have become increasingly serious, and energy management and the design of power supply and distribution have become hot problems; efficient and reliable power distribution system scheme for data center is an effective method to improve the power utilization efficiency of the data center and reduce the energy consumption of equipment. In order to achieve the energy conservation of data center, firstly it is necessary to accurately monitor each electricity load, but there are many loading circuits in the data center, and the traditional measuring instruments are incapable of satisfying the requirements for cost, volume, installation, construction and the like; hence, it is necessary to apply multi-circuit monitoring device applicable to the centralized monitoring requirements of data center.
AMC16 series multi-circuit monitoring device of Acrel Company is a measuring device designed
specifically for the power supply management of server in the data center. Such device is small and exquisite in design, capable of centralized monitoring on various electric parameters and on-off states of dozens of circuits, including incoming line circuit and outgoing line circuit, and it achieves the highly integration of monitoring circuits in volume.
Technical parameter
Technical parameter | AMC16Z-ZA | |
Measured parameter | Voltage, current, frequency, active power, reactive power, power factor, active power, reactive power |
|
Zero ground voltage, neutral line current, total harmonic content (THD), ), peak voltage, voltage and current sequence quantity, |
||
Busbar voltage | Rated | 220VAC |
Measurement | ±20% | |
Overload |
Instant voltage 2times/second
|
|
Current incoming circuit | Rated | Twice 5A |
Range | 0~6A | |
Overload | Duration 1.2 times, instantaneous 10 times/second | |
Temp &humidity | Temp range | -40℃~+99℃ |
humidity range | 20%~90% | |
Input frequency
|
45~60Hz | |
Measurement precision | Inlet wire | Voltage/current level 0.2, active power/electric energy level 0.5, reactive power/electric energy level 1 |
Temp | ±1℃ | |
Humidity | ±5% | |
Auxiliary power supply | Take electric signal(≤15W) | |
Environment | Temp | Working:-15℃~55℃ Storage:-25℃~70℃ |
Humidity | Relative humidity ≤93% | |
Altitude | ≤2500m | |
Switch output | 2-way 3A 250VAC/3A 30VDC | |
Switch input | 6-way dry contact | |
Communication | RS485/Modbus-RTU | |
Installation method | DIN35mm Guide rail or bottom plate mounting |