Acrel AMC96L-E4/KC Multifunction 3 phase Power Meter for industrial and commercial fields with measurement
Contact Person : Dina Huang
Phone Number : 18761502682
WhatsApp : +8618761502682
| 
                                     Detail Information  | 
                            |||
| Measurement: | 3-phase AC KWh, KVarh, I, U, KW, KVar, Hz, Cosφ And Etc | Rated Voltage: | 220v/380v | 
|---|---|---|---|
| Rated Current: | 1A/5A | Communication: | RS485 (MODBUS-RTU) | 
| SOE Funciton: | Event&Demand&Extremum Record | Harmonic Measurement: | 2~31st And Total Harmonic | 
| Analog Output: | 4~20mA DC Or 1~5V DC | ||
| Highlight: | total Harmonic AC Energy Meter,AMC Series AC Panel Meter,Digital Multifunction Power Meter | 
                                                                    ||
Product Description
AMC series programmable intelligent meters, adopting AC sampling technology, can directly or indirectly measure electric voltage and current of single-phase or three-phase grid. It can be used for local display, and connecting industrial control devices to form measuring control systems.
Panel overview
![]()
| Function | Description&Value | |
| Measurement | 3-phase AC kWh, kVarh, I, U, kW, kVar, Hz, cosφ and etc | |
| Display | LCD display | |
Communication (Optional)  | 
			
			 RS485,Modbus-RTU protocol;  | 
		|
Alarm Output (Optional)  | 
			
			 1 channel passive relay,contact capacity 3A/30VDC,3A/250VAC, Used for high,low,unbalance alarm etc.  | 
		|
DI/DO Switching (Optional)  | 
			
			 DI (Digital input): 2-channel or 4-channel dry contact digital input with built in power supply DO (Digital output): 2-channel digital output with NO relay contact. Capacity: 3A/30V DC,3A/250V AC  | 
		|
| Input | Rated Voltage | 
			 AC Voltage Input: 400V AC L-L (via direct connetion); 100V AC L-L (via -/100V AC PTs)  | 
		
| Rated Current | 
			 AC Current Input: 5A AC or 1A AC (via -/5A AC or -/1A AC CTs)  | 
		|
| Overload | Current&Voltage input overload:1.2 times rated value(continuous); 10 times rated value /1 second | |
| Measuring Accuracy | Active Power | 
			 0.5%  | 
		
| kWh | 0.5% | |
| kVarh | 1.0% | |
| Insulation resistance | 
			 ≥ 100MΩ  | 
		|
| Power frequency withstand voltage | 
			 Between Power supply//Switching Output// Current Input//voltage Input and Transmitting// Communication //Pulse Output//switching input AC 2 kV 1min; Between Power supply,switching output,Current Input,voltage Input AC 2 kV 1min; Between Transmitting,Communication,Pulse Output,switching input AC 1kV 1 min;  | 
		|
![]()
![]()
Enter Your Message