Detail Information |
|||
Phase: | Three Phase | Display Type: | LCD |
---|---|---|---|
Accuracy Class: | 0.5% | Operating Temperature: | -25℃~+55℃ |
Dimensions: | 90*72mm | Width Of Pulse: | 80±20ms |
High Light: | 3 phase DIN rail energy meter,DIN rail mounted energy meter,3 phase electricity meter |
Product Description
Project |
Performance parameter | ||
Specification | 3 phase 3 wires, 3 phase 4 wires | ||
Measurement | Voltage | Reference voltage | 3×100V3×380Vac,3×57.7/100Vac, 3×220/380Vac (Can normally work under 1.2 times of rated voltage) |
Consumption | <10VA(Single phase) | ||
Impedance | >2MΩ | ||
Accuracy class | Error±0.2% | ||
Current | Input current | 3×1(6)A, 3×10(80)A | |
Consumption | <1VA Single phase rated current | ||
Accuracy class | Error±0.2% | ||
Power | Active, reactive, apparent power, error±0.5℅ | ||
Frequency | 45~65Hz,Error±0.2% | ||
Metering | Energy | Active energy(Accuracy class: 0.5) reactive energy(Accuracy class 2) | |
Clock | ≤0.5s/d | ||
Digit signal | Energy pulse output | 1 active photocoupler output | |
Pulse | Width of pulse | 80±20ms | |
Pulse constant | 400imp/kWh,10000imp/kWh(Correspond with the basic current) | ||
Communication | Interface and communication protocol | RS485:Modbus RTU | |
Range of Communication address | Modbus RTU:1~ 247; | ||
Baud rate | 1200bps~19200bps | ||
Environment | Working temperature | -25℃~+55℃ | |
Relative humidity | ≤95℅(No condensation) |