Free call

400V 690V Ac Electricity Meter / Ac 3 Phase 4 Wire Static Kwh Meter

Minimum Order Quantity : 1 Price : USD 355-385 PCS
Delivery Time : 5-8 work days Payment Terms : L/C, T/T
Supply Ability : 2000000 per day
Place of Origin: Jiangsu, China Brand Name: Acrel
Certification: ISO/CE Model Number: APM810

Detail Information

High Light:

690V Ac Electricity Meter

,

400V Ac Electricity Meter

,

Ac 3 Phase 4 Wire Static Kwh Meter

Product Description

APM810 Multifunction Meter
● True RMS Measurements
● THD with 63rd Harmonics
● K-Factor and Crest Factor
● Unbalance & Phase Angles
● Demands and Multi-Tariff energy
● Max/Min Log with Timestamp

 

Characteristic
400V 690V Ac Electricity Meter / Ac 3 Phase 4 Wire Static Kwh Meter 0400V 690V Ac Electricity Meter / Ac 3 Phase 4 Wire Static Kwh Meter 1400V 690V Ac Electricity Meter / Ac 3 Phase 4 Wire Static Kwh Meter 2
CommunicationDisplayRated U and I

Standard: RS485(Modbus-RTU)

Optional: Profibus((Profibus-DP), Ethernet(Modbus-TCP, HTTP, DHCP)

LCD display U,I,P,Q,PF,kWh and other energy consumption, power measurement, harmonic content

Voltage: AC 100V,110V,400V,690V; Current:AC 1A,5A, support2 mm² line access;

 
Function & Parameter

Connection
3 phase 3 wire, 3 phase 4 wire
Frequency
50Hz
 
Input Voltage
Rated Voltage
AC 100V, 110V, 400V, 690V
Overload
1.2 times rated value(continuous); 2 times rated value(1 second)
Consumption
<0.5VA(per channel)
 
Input Current
Rated Voltage
AC 1A, 5A
Overload
1.2 times rated value(continuous); 2 times rated value(1 second)
Consumption
<0.5VA(per channel)
 
 
Accuracy
Voltage, current and power
 
Class 0.5S(APM800, APM810)
Class 0.2S(APM801, APM830)
Active power
Reactive power
Class 2
Harmonic
1%(2-42nd), 2%(43-63rd)
Switch inputs
Passive contact inputs, built-in power supply
Relay outputs
Contact type: open contact in main part, changeover contact in module
Pulse capacity: 3A/AC250V, 3A/DC30V
Pulse output of energy
Output mode: Optocoupler pulse with open collector
Pulse constant: 4000(5A), 8000(1A) imp/kWh
Analog output
DC0-20mA, 4-20mA, 0-5V, 1-5V output, accuracy class 0.5%,
Load resistance≤500Ω
Analog input
DC0-20mA, 4-20mA, 0-5V, 1-5V input, accuracy class 0.5%,
Storage card
Standard capacity: 4G, TF card up to 32G capacity
Communication
RS485(Modbus-RTU), Profibus(Profibus-DP),
Ethernet(Modbus-TCP, HTTP, DHCP)
Auxiliary power supply
AC/DC 85~265V or AC/DC 115~415V
Electromagnetic compatibility
IEC 61000 standard(Level 4)
 
 
Environment
Operating temperature
-20~65℃
Storing temperature
-20~70℃
Humidity
≤95%(No condensation)
Altitude
≤2500m

 
LCD Display
400V 690V Ac Electricity Meter / Ac 3 Phase 4 Wire Static Kwh Meter 3
 
Wiring

400V 690V Ac Electricity Meter / Ac 3 Phase 4 Wire Static Kwh Meter 4

Typical connection

400V 690V Ac Electricity Meter / Ac 3 Phase 4 Wire Static Kwh Meter 5

You Might Be Into These
Get in touch with us

Enter Your Message

ella.wong@email.acrel.cn
+8618761502682
18761502682
18761502682
18761502682