class 0.2 DC 4-20mA Electric Current Transducers BA10-AI Series

Minimum Order Quantity : 1 Price : USD 22-67 pcs
Packaging Details : 48*45.5*20 Delivery Time : 5-8 work days
Payment Terms : L/C, T/T Supply Ability : 2000000 pcs per year
Place of Origin: Jiangsu, China Brand Name: Acrel
Certification: ISO/CE Model Number: BA10-AI-V/I

Detail Information

Input: 0-1A Leakage Current Output: DC 4-20mA Or DC 0-5V
Overload: 1.2 Times Of Rated Value
High Light:

DC 20mA Electric Current Transducers

,

DC 20mA leakage current sensor

,

class 0.2 Electric Current Transducers

Product Description

BA10-AI Series Current Transducer

BA series conduct the real-time measurement on the alternating current in the power grid according to the electromagnetic induction theory. They utilize the precise constant current technology and the linear temperature compensation technology to isolate and convert the measured current into the DC signal. They adopt the 24V or 12V power supply. They feature the large overload capacity,high accuracy,isolation and safety and low power consumption.Application cover the industrial automation sector.

 

BA series residual current sensors are designed to monitor the electric leakage and detect the insulation of electrical circuit or electrical equipment in order to avoid accidents arising from reduction of insulation performance of electrical circuit or electrical equipment.The product complies with GB/T13850-1998 and GB1208-2006.

 

Application

Industrial automation

 

Technical Parameters

ModelTechnical parameters BA05 BA10 BA20BA50
Accuracy 0.5class,0.2class
Input Nominal value AC0~(0.5~10)A AC 0~( 8~50)A AC 0~(40~200)A AC 0~(60~600)A
  Overload Continual1.2 times, Instantaneous current 10 times/1s:
  Absorbed power ≤1VA
  Frequency response 25Hz~800Hz(average), 25~5kHz(true RMS),specially suitable for power frequency application
Output Nominal value DC4~20mA,or 0~20mA,0~5V,0~10V(And so on)
  Load resistance Current output ≤500Ω , Voltage output≥1KΩ
Response time Average≤350ms, true RMS≤100ms
Power supply Voltage DC12V or 24V
  Consumption ≤1W
Insulation resistance >100MΩ
Isolation voltage (Among input//output//power supply)2.0kV/1min,50Hz
Temperature modulus -10℃~+55℃,≤100ppm/℃
Environment Temperature Work:-10℃~+55℃ Storage:-25℃~+70℃
  Humidity ≤93%RH,(In the place without dew and corrosive gas)
  Altitude ≤2000m
Installation (TS35 rail mounting, or attached with screws in of the cabinet)

 

 

Function

Model Product function Perforation(mm) Enter the nominal value range
BA05-AI/I(V)

0-10A AC current signal acquisition,

output 4-20mA or 0-5V DC signal

Φ5 AC0~(0.5~10)A
BA05-AI/I(V)-T
BA10-AI/I(V)

0-50A AC current signal acquisition,

output 4-20mA or 0-5V DC signal

Φ10 AC0~(8~50)A
BA10-AI/I(V)-T
BA20-AI/I(V)

AC 0-200A current signal acquisition,

output 4-20mA or 0-5V DC signal

Φ20 AC0~(40~200)A
BA20-AI/I(V)-T
BA50-AI/I(V)

AC 0-600A current signal acquisition,

output 4-20mA or 0-5V DC signal

Φ50 AC0~(60~600)A
BA50-AI/I(V)-T

 

 