AMC16MA Data Center Monitor Device
● Designed specifically for the power supply management of server in the data center
● Including 2 incoming line circuit and 36 outgoing line circuit
● U, I, P, Q, S, PF, kWh, kvarh
● Optional 2nd-15th harmonic
 
Characteristic

ISO 2 Channels Inlet Multi Circuit Energy Meter Data Center Monitor Device 0ISO 2 Channels Inlet Multi Circuit Energy Meter Data Center Monitor Device 1ISO 2 Channels Inlet Multi Circuit Energy Meter Data Center Monitor Device 2
Communication

Multi-circuit

Rated U and I
RS485 (Modbus-RTU)

2 channels inlet

36 channels outlet

AC 220/380V

 
Function

Three-phase 2 channels inlet voltage, current, active power, reactive power, power factor, active energy, reactive energy
 
Single-phase 36 channels outlet (Three-phase 12 channels outlet) voltage, current, active power, reactive power, power factor, active energy, reactive energy
1 on-off output
2 RS485 communication
 
Installation:
DIN 35mm
 
Dimension(L*W*H):
194*124*88mm
 

Technical parameters

Bus bar voltage

Rated voltage

220V

Range

40~400V AC

Overload

1.2 times(continuous),10 times lasting 1s(instantaneous)

Current

Inlet CT

XXA /5A

Inlet Range

0~10A

Outlet CT

1000A/20mA

Outlet Range

0~120%

Overload

1.2 times for continuous,10 times/5s for instantaneous

Accuracy

Inlet

Class 1.0

Outlet

Class 2.0

Frequency

45~65Hz,±0.2%

Auxiliary power supply

AC 85~265V/DC 100~350V

Insulation resisitance

100MΩ

Switching output

5A 250VAC/5A 30VDC

Communication

RS485(Modbus-RTU)

Environment

Temperature

Operation:-15℃~55℃ Storage:-25℃~70℃

Humidity

≤93%(No condensation)

Altitude

≤2500m

Installation

Din rail 35mm

 
Wring
ISO 2 Channels Inlet Multi Circuit Energy Meter Data Center Monitor Device 3
 
Typical connection
ISO 2 Channels Inlet Multi Circuit Energy Meter Data Center Monitor Device 4
 

You Might Be Into These
Get in touch with us

Enter Your Message

ella.wong@email.acrel.cn
+8618761502682
18761502682
18761502682
18761502682