RS 485 high Accuracy Temperature Humidity Multi Sensor ODM
Contact Person : Dina Huang
Phone Number : 18761502682
WhatsApp : +8618761502682
Detail Information |
|||
Display: | LED Display | Communication: | RS485 Port MODBUS-RTU Protocol |
---|---|---|---|
Certificate: | CE ISO9001 | Consumption: | Auxiliary Power Supply |
Installation: | Panel Mounted | Accuracy: | Temperature ±1℃ Humidity ±5%RH |
Auxiliary Power Supply: | AC 85~265V DC 100~350V | Temperature: | -20℃~+60℃ |
Humidity: | ≤95%RH(No Condensation) | Contact Capacity: | 5A/AC250V |
Selling Units: | Single Item | Single Package Size : | 7.5X7.5X9.1 Cm |
Single Gross Weight: | 1.500 Kg | Package Type: | It Is Packed In A Crash Bag And Then Put Into A Cardboard Box. |
Product Description
Technical Parameter
|
|
Value
|
|
Measuring range
|
Temperature
|
-40.0℃~99.9℃
|
|
|
Humidity
|
20%RH~90%RH
|
|
Accuracy
|
Temperature
|
±1℃
|
|
|
Humidity
|
±5%RH
|
|
Analog output
|
|
DC 4~20mA
|
|
Set range of controlling parameter
|
Heating for Temperature rising
|
-40.0℃~40.0℃
|
|
|
Blowing for temperature decreasing
|
0℃~99.9℃
|
|
|
Humidity control
|
20%RH~90%RH
|
|
Contact capacity
|
|
5A/AC250V
|
|
Communication
|
|
RS485(MODBUS-RTU)
|
|
Auxiliary power supply
|
Working range
|
AC 85~265V DC 100~350V
|
|
|
Consumption
|
Basic power consumption(≤0.8w)+ relay power consumption(each channel≤0.7w)
|
|
Insulation resistance
|
|
≥100MΩ
|
|
Environment
|
Temperature
|
-20℃~+60℃
|
|
|
Humidity
|
≤95%RH(No condensation)
|
|
|
Altitude
|
≤2500 m
|