Acrel AHKC-BS AC DC Hall Effect Current Sensor Static Converters For Motor Drivers
Contact Person : Dina Huang
Phone Number : 18761502682
WhatsApp : +8618761502682
Detail Information |
|||
Usage: | Magnetic Sensor | Theory: | Hall Sensor |
---|---|---|---|
Output: | Analog SENSOR | Rated Current: | DC 10mA-2A |
Power Supply: | 12V/24V | Rated Output: | 0-5V |
Precision Degree: | 1.0 | Operating Temperature: | _40℃~+85℃ |
Storage Temperature: | _40℃~+85℃ | Humidity: | ≤95%RH,no Dew,no Aggressive Gas |
Altitude: | ≤3500m | Product Name: | Hall-effect Voltage Sensor |
Selling Units: | Single Item | Single Package Size : | 10X10X5 Cm |
Single Gross Weight: | 5.000 Kg | Package Type: | Carton Box |
High Light: | 24V DC Leakage Current Sensor,12V DC Leakage Current Sensor,24V dc hall effect sensor |
Product Description
DC leakage current sensor
DC leakage current sensor is a measuring module that converts the measured direct current into the proportional direct current or voltage signal according to the flux gate theory and the input side is highly insulated from the output side. Typical outputs include 4-20mA, DC0-5V and DC0-10V signals. These standard signals can be acquired by various devices such as PLC, RTU and DAS card and used for different current monitoring applications. leakage current transformerS surround the outlet + and – of DC circuit. It detects output signals of sensors in circuit branches. If the insulation in circuit branches is normal, the current passing the sensor must be equal in the opposite direction. The output signal is zero. If a circuit branch is grounded, the differential current passes the leakage current transformer and the output of sensor is not zero.Therefore, it is possible to identify the grounded branch in the DC system by detecting output signals from circuit branches.The theory guarantees the accurate line identification and prevents the influence of distributed capacitance.
Spec. and size (unit:mm)
Size specification |
Outline size(mm) |
Through size(mm) |
Mounting size(mm) |
Figure |
||||
W |
H |
D |
Φ2 |
Φ1 |
M |
N |
||
AHLC-LTA |
68 |
57 |
20 |
50 |
20 |
52 |
52 |
Fig.1 |
AHLC-EA |
100 |
108 |
30 |
75 |
40 |
78 |
/ |
Fig.2 |
AHLC-EB |
120 |
112 |
30 |
94 |
60 |
98 |
/ |
Fig.3 |
parameter
Specification |
Rated current |
Power supply |
Rated output |
Measuring aperture (mm) |
Precision degree |
AHLC-LTA |
DC 10mA~2A |
±15V |
5V |
φ20 |
1 |
AHLC-EA |
DC 10mA~2A |
±15V |
5V |
φ40 |
1 |
AHLC-EB |
DC 10mA~2A |
±15V |
5V |
φ60 |
1 |
Definition of wiring terminals
Enter Your Message