Acrel ANSVG Static Var Generator Used For Reactive Power Compensation Harmonic Control And Unbalance Adjustment
Contact Person : Dina Huang
Phone Number : 18761502682
WhatsApp : +8618761502682
Minimum Order Quantity : | 1 | Packaging Details : | 45*62.2*2 cm |
---|---|---|---|
Delivery Time : | 10-28 work days | Payment Terms : | L/C, T/T |
Supply Ability : | 10000 pcs per year |
Place of Origin: | Jiangsu,China | Brand Name: | Acrel |
---|---|---|---|
Certification: | ISO/CE | Model Number: | ANAPF |
Detail Information |
|||
Communication: | RS485(Modbus-RTU)or Ethernet(Modbus-TCP) Standard Or Customized | Display: | LCD |
---|---|---|---|
Accuracy Class: | 2 | Rated U: | 380V±15% |
Frequency: | 50Hz±2% | Rated I: | 30A,50A,75A, 100A Or 150A |
Highlight: | ANAPF Active Power Filter,380V active harmonic filter,Active Power Filter 380V |
Product Description
The ideal voltage and current waveforms in the power system are sine waves with a frequency of 50 Hz, however, the wide-ranging applications of nonlinear power equipment (such as high-power thyristors, inverters, UPS, switching power supplies, intermediate frequency furnaces, energy-saving lamps, etc.) generates a large amount of distorted harmonic current. Harmonic current coupling will generate harmonic voltage on the line. The Fourier series decomposition is performed on the non-sinusoidal distortion current, wherein the component whose frequency is the same as the power frequency is the fundamental wave, and the component whose frequency is an integer multiple of the fundamental frequency is the harmonic. This type of harmonic "pollution" could cause great harm to the power grid and users, so harmonic management is called as a "green project."
Due to the development of power electronics technology, active power filter (APF) began to scale application. Compared with the traditional harmonic suppression and reactive power compensation device, APF has a fast response, could real-time tracking and compensation for each harmonic, and has the functions of compensating for harmonics, reactive power compensation and balancing three-phase current. At the same time, APF has the advantages of not being affected by system impedance, no hidden danger of resonance, high compensation efficiency, and has been widely used in power supply systems of various industries.
Flexible compensation method:Compensate for harmonics only, compensate for reactive power only, compensate for both harmonics and reactive power,could compensate for 2th-25th harmonics or compensate for specific harmonics;
Ability of managing three-phase imbalance;
Linear compensation,Response time ≤ 5ms;
Humanized human-computer interaction interface, which displays real-time power quality information of the system and the ontology. This interface has the ability to control the device remotely and easy to operate;
Adopt imported IGBT which has high power density and high reliability;
Using DSP digital control system for high speed detection and calculation;
With remote communication interface, real-time monitoring through PC;
Standard modular design which reduces lead times and increases reliability and maintainability.
Response time
Full response time≤5ms,Instantaneous response time≤100μs
Total harmonic compensation rate
≥ 97%,3th/5th/7th/9th independent compensation rate ≥ 98%
Self-loss
≤2%
Efficiency
≥98%
Switching frequency
20KHz
Wiring method | Three-phase three-wire or three-phase four-wire |
Access voltage | 3×380V ±10% |
Access frequency | 50Hz ±2% |
Response time | Full response time≤10ms,Instantaneous response time≤100μs |
Switching frequency | 10-20kHz |
Function setting | Compensate for harmonics only, compensate for reactive power only, compensate for both harmonics and reactive power |
Times of harmonic compensation | 2th -51th |
Type of protection | DC overvoltage protection, IGBT overcurrent protection, device over temperature protection |
Cooling method | Forced air cooling |
Noise | < 65dB |
Working temperature | -10℃~+45℃ |
Working humidity | <85%RH Non-condensing |
Installation occasion | Indoor installation |
Main interface
System information interface
Fault information interface
Parameter setting interface